G301 - Generator Control Concepts

| Print |

3 days - 1.9 Continuing Education Units Awarded



Course Dates Download Brochure PDF
USD 1,895.00


There are NO SMALL PROBLEMS when it comes to your GENERATOR!!  Be prepared.  Make sure you fully understand Design, Construction, Operations, and how /why the controls function as they do.  Don't be surprised.  Be prepared.  Register for this Seminar today.  We begin with the big-picture, proceed with component identification (including how these components may be of risk in abnormal conditions), discussion of normal/abnormal operations, and how the generator controls should respond to these conditions.  This Seminar is designed for plant engineers who have a specific need to better understand how the generator controls function.  Plant electrical and operations technicians benefit as well.
Topics include: Generator Theory • System Operation • Generator Construction • Exciters • Voltage Regulators • Speed Controls • Generator Protection • Industry Events
OBJECTIVES:
Upon successful completion of this Seminar the participant will be able to:
  1. Describe how a generator functions. (Learn why and how the voltage drops with an application of a load and learn why and how the rotor speed and angle change as that load is applied)
  2. Describe active and reactive power. (Learn how active power is generated, how reactive power is generated, and how these loads are shared from one generator to another)
  3. Describe the major components used in the construction of an AC generator
  4. Learn how these components are at risk during mis- or abnormal operations
  5. Explain operation and maintenance of the most common excitation systems
  6. Explain how a speed governor alters generator output in response to a frequency deviation. (Learn why the speed changes when a load is applied. Learn what is the role of the governor is response to this speed/frequency change)
  7. Explain how the voltage regulator alters generator output in response to a voltage deviation. (Furthermore, learn why the voltage drops, how a voltage drop is detected, where it is detected, and how the voltage regulator responds as it does)
  8. Discuss the causes and effects of both voltage and frequency oscillations and the impact they each have on power system dynamics
  9. Describe generator normal/safe startup and shutdown procedures
  10. Describe why the generator synchronizing process is as it is. (Learn what are the results of not checking phase rotation, of mismatching voltages, of mismatching frequencies, and closing the circuit breaker out-of-phase)
  11. Discuss abnormal generator operation and recommended actions for generator protection
  12. Given an unfortunate abnormal condition, describe possible results to equipment and/or system
OUTLINE:
  1. Monday
    1. Generator Theory: Armature Reaction, Resistive Loads, Inductive Loads, Capacitive Loads, Power Transfer and Load Angle, Reactive Power, Net Air Gap, Developed Torque, Watt and VAR Control, Generator Capability, Stator Winding Heating, Field Heating, Core End Iron Heating, Power System, Power Transfer Between Generator Rotor and Stator, Short Circuit Ratio
    2. System Operations: Structure of the Power System, Interconnections, Power Balance, Operation of the System, State of the Power System
  2. Tuesday
    1. Generator Construction: Stator Frame, Core, Windings, End Shield, Rotor Body, Field Windings, Retaining Rings, Collector Rings, Diesel and Hydroelectric Differences
    2. Excitation Systems, Voltage & Frequency Control: Speed Governor Response to Frequency Deviations, Automatic Voltage Regulator Response to Voltage Deviations, Manual Regulator, URAL, Impedance Compensator, Volts/Hertz, Maximum Excitation Limit, Transfer & Tracking, PSS, De-Excitation, Steady State Operation, Transient Conditions, Earlier Excitation Systems, Rotating AC Exciters, Alterrex, SCRs, Brushless Excitation Systems, Static Excitation Systems, SCPT, SCT-PPT, Bus Fed Exciters
    3. Generator Auxiliary Systems: Purpose and Operations of the Generator Hydrogen Control System, Generator Seal Oil System, and Stator Liquid Cooling System (as required)
  3. Wednesday
    1. Normal Operations: Preparation for Start-Up, Synchronizing, Load Changes, Use of Reactive Capability Curve, Shutdown
    2. Abnormal Operations: Relationships Between Operations, Protection and Alarms; Alarms, Protection when Off-Line, Tripping Methods, Protective Actions for Generator Faults and Abnormal Operations & Protection Recommendations: System Steady & Dynamic Conditions, Frequency Deviations, Voltage Deviations, Instabilities, Loss of Synchronism, Stator Overcurrent, Field Ground, Stator Ground Fault, Stator Phase-to-Phase Fault, Over Voltage, Over Volts-per-Hertz, Field Overheating, Loss of Excitation, Bearing Vibration, Synchronizing Errors, Motoring, Seal Oil System Pressure, Stator Coolant System, Local Overheating, Unbalanced Armature Currents, Breaker Failures, System Back Up, Voltage Surges, Transmission Line Planned Switching, High Speed Reclosing, Accidental Energization

SATISFIED CLIENTS: Alstom Power, AmerGen Energy, Arizona PSC, Associated Electric Cooperative, Cardinal Operating Company, Cayman Islands Utilities, Chelan County PUD, Connectiv Operating Services, Detroit Edison, Dynegy Power, Edison Mission Energy, El Paso Electric, Enron, Entergy-Arkansas, Entergy-Louisiana, Entertainment & Engineering Operations, Exelon Nuclear, Exxon-Mobil, Hawthorne Power Services, Iberdola (Spain), Institute for Nuclear Power Operators (INPO), International Paper, Kansas City Board of Public Utilities, Korea Plant Services & Engineering, L&S Industries, Madison Gas & Electric, MidAmerican Energy, New England Power, North America Energy Services, Oklahoma Gas & Electric, Orange County Sanitation Department, Orrville City (OH) Utilities, Portland G&E, Pyro-Pacific Cogen, SaskPower, Seattle City Lighting, Sierra Pacific Power, Sithe Energies, Southern California Edison, Southwestern Electric Power, Tennessee Valley Authority, Texas Municipal Power Agency, US Army Corps of Engineers, US Bureau of Reclamation, US Navy and Vermont Yankee